Excessive exhaust temperature of hydrogen compressor may be caused by the following reasons:
1. Improper operation: parameter adjustment error (such as wrong setting of pressure or cooling system);
2. Mechanical failure: bearing damage, aging seal, cylinder valve plate damage or piston wear;
3. Abnormal cooling system: the cooling water is interrupted, the water temperature is too high or the flow rate is insufficient;
4. Lubrication problem: insufficient or inferior lubricating oil leads to increased friction;
5. Environmental factors: the exhaust port is blocked or the ambient temperature is too high.
Summary: If the exhaust temperature of hydrogen compressor is too high, it should be handled in time, otherwise it may lead to lubrication failure, permanent damage of components and even safety accidents.